xPortalNet - Alarm Monitoring System
The xPortalNet system supports alarm
monitoring system. It uses the following MicroEngine's alarm
Processor
- Mio-S168 - 16 supervised inputs and 8
relay outputs
- Mio-R16 - 16 relay outputs
- Mio-L32 - 32 LED drivers (for mimic
panel)
The CP-CNET controller will automatically
process the alarm messages and react in accordance to the
event programs stored inside the memory even without the
intervention of the security officer.
Unlike digital input sensor, the sensor
inputs connected to our alarm boards are electronically
supervised. The alarm processor is able to detect whether
the sensor wire has been bypassed or cut as long as the
sensor is probably installed following our installation
guidelines.
The alarm processor has built-in relay
output that can be configured as alarm output, time
controlled output or general purpose output. You can even
program an output to be triggered by an alarm event, such as
in the case of connecting the relay output to a video
recorder and the relay will be used to trigger video
recorder to record from a particular CCTV when an alarm
occurs.
Should you require Alarm Mimic Panel to
be installed in your security room, we have the LED display
processor board to be used to display the status of the
alarm sensors on the mimic panel using LEDs.
With the LED display, the sensor status
can be clearly shown in the security control room mimic
panel.
Most of the security devices such as
smoke detectors, magnetic contacts, motion detectors, and
seismic sensors can be connected to our alarm processor
without any problem. The zone arming can be activated either
by manually, time zone controlled or group controlled.
The FEP is connected back to the computer
for real time reporting and management. The SAS computer
software continuously displays the status of each of the
sensor on the computer. These alarm event can be displayed
either in the form of text list or floor plan map. The
computer buzzer will also be alerted whenever there is an
alarm.
XP-CNET - Access and Alarm Controller
- Acts as the central processor for the alarm events
and output of the system
- 512 Sensor Points
- 256 Output Points
- 99 Event Programs
- Onboard memory and Real-Time-Clock
- Onboard System Integrity Monitoring System (SIMS)
- Power Input : 12VDC @ 400mA
MTA-S168Input Capture Processor
- 16 Supervised Input/8 Relay Output Alarm
Processor
- 16 Supervised Input
- 8 Relay Output
- Onboard System Integrity Monitoring System
(SIMS)
- Power Input : 12VDC @ 250mA
MTA-L32Output Driver Processor
- 32 Open Collector Output Driver (Can be used to
switch on LED or Relay)
- 2 Relay Output
- 2 Digital Input
- Onboard System Integrity Monitoring System
(SIMS)
- Power Input : 12VDC @ 350mA
MR-1616 Relay Output Processor
- 16 Relay Outputs
- 2 Digital Inputs
- Onboard System Integrity Monitoring System
(SIMS)
- Power Input : 12VDC @ 350mA
|